Limited time offer: Connecticut Home Energy Solutions (HES) program for a reduced co-pay amount starting at $75. Learn more...
GUARDIAN’s 7 kW is clearly the most affordable automatic standby generator on the market. For a modest investment you can power all of your home’s essential circuits, including your living room, family room, kitchen, bathroom, bedroom, furnace, well pump and window air conditioner.
There’s no need to worry about individual items because everything on the circuits you choose is protected… lights, plug-in appliances, electronics, air conditioner… everything!
Plus, GUARDIAN’s 7 kW comes as a pre-packaged, pre-wired system, so it’s the easiest system on the market to install. That’s just one more reason why GUARDIAN is America’s #1 selling brand.
| Rated Power LP (kW) | 7 |
| Rated Power NG (kW) | 6 |
| Voltage @ 60 Hz | 120/240 |
| Phase | Single |
| Frequency | 60 Hz |
| Amps LP | 58.3/29.2 |
| Amps NG | 50.0/25.0 |
| Engine/Alternator RPM | 3600/3600 |
| Engine | 410cc 14.5 HP Generac OHVI Single Cylinder |
| Fuel Consumption LP (cu.ft./hr.)/(gal./hr.) | 54 (1.47) |
| Fuel Consumption NG (cu.ft./hr.) | 119 |
| EPA/CARB Certified | Yes |
| Fuel | Natural Gas/LP Vapor |
| Engine Cooling | Air |
| UL 2200 (US and Canada) | Yes |
| Main Line Circuit Breaker | 30 Amp |
| Dimensions (L" x W" x H") | 48 x 24 x 28-1/4 |
| Unit Wt. (lbs.) | 336 |
| Engine Start Sequence | Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration |
| Automatic Low Oil Shutdown | Standard |
| Overspeed Shutdown | Standard, 72 Hz |
| Overcrank Protection | Standard |
| Automatic Voltage Regulator with Over-Voltage Protection | Standard |
| Engine Warmup | 10 seconds |
| Engine Cool-Down | 1 minute |
| Safety Fuse | Standard |
| 2.5 Amp Timed Trickle Battery Charger | Standard |
| Auto Switch | Automatic start on utility failure/7 day exercise |
| Off Switch | Stops unit. Power is removed. Control and charger still operate |
| Manual / Test (start) | Start with starter control, unit stays on. If utility fails, transfer to load takes place |
| Full Monitoring System | Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing |
| Shutdown and LED Indicators | Overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage |
| No. of Poles | 2 |
| Current Rating (amps) | 100 |
| Voltage Rating (VAC) | 250 |
| Utility Voltage Monitor (fixed) | - Pick-up: 70% - Drop out: 60% |
| Return to Utility | Approx. 13 seconds |
| Exercised 7 minutes weekly | Standard |
| UL Listed | Yes |
| Dimensions (H" x W" x D") | 26.5 x 12.5 x 7 |
Serving the Greater New Haven and Fairfield area